Item type |
学位論文 / Thesis or Dissertation(1) |
公開日 |
2014-04-28 |
タイトル |
|
|
タイトル |
The Effects of Implant Surface Characteristics on Surrounding Bone: A Comparative Study of Two Types of Surface Characteristics |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題 |
Implant |
キーワード |
|
|
主題 |
Surface characteristics |
キーワード |
|
|
主題 |
Titanium coating |
キーワード |
|
|
主題 |
Micro-CT |
キーワード |
|
|
主題 |
Animal study |
キーワード |
|
|
言語 |
en |
|
主題 |
Implant |
キーワード |
|
|
言語 |
en |
|
主題 |
Surface characteristics |
キーワード |
|
|
言語 |
en |
|
主題 |
Titanium coating |
キーワード |
|
|
言語 |
en |
|
主題 |
Micro-CT |
キーワード |
|
|
言語 |
en |
|
主題 |
Animal study |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_db06 |
|
資源タイプ |
doctoral thesis |
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
著者 |
Yamamoto, Kazuko
Yanagi, Tsukasa
Watazu, Akira
Teraoka, Kay
Kido, Hirofumi
|
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
The aims of this study were to create experimental implants by coating rough plastic surfaces with a thin layer of titanium, and to use the experimental implants in an animal experiment to investigate whether differences in the surface characteristics of the implant affect the peri-implant bone reaction during the period of osseointegration. Titanium rods of diameter 1.6 mm and length 7 mm were treated by acid etching (AE) or sandblasting followed by acid etching (SA), and replicas were made from plastic. Experimental implants were created by depositing a thin layer of titanium on the plastic replicas by DC-magnetron sputtering, and the surface characteristics of the experimental implants were evaluated. The experimental implants were placed in the tibias of eight-week-old male SD rats. The rats were sacrificed and the implants harvested at 3, 5, 10, 14, 21 and 28 days after implant placement. The samples were examined by optical microscopy and micro-CT to confirm peri-implant new bone growth. Examination of the experimental implants by SEM imaging showed that the different surface conditions (SA and AE) had been faithfully recreated. TEM observation and XPS analysis confirmed that the coating was titanium. The surface roughness of SA and AE was 2.68±0.536 μm and 0.47±0.069 μm, respectively. With AE, the BMD of peri-implant trabecular bone showed that bone mineralization progressed not on the surface of the implant but at sites a small distance away. At day 28 after placement of the implant, when osseointegration was complete, the BMD value in the region near the implant surface was higher in SA than in AE. Furthermore, the BV/TV value was high at an earlier stage in SA than AE. The results showed that the SA surface was better than the AE surface for achieving osseointegration. |
学位名 |
|
|
学位名 |
博士(歯学) |
学位授与大学 |
|
|
|
学位授与機関識別子 |
37114 |
|
|
学位授与機関名 |
福岡歯科大学 |
学位授与年度 |
|
|
内容記述 |
2013年度 |
学位授与年月日 |
|
|
学位授与年月日 |
2014-03-15 |
報告番号 |
|
|
学位授与番号 |
甲第251号 |
情報源 |
|
|
|
関連名称 |
Journal of Hard Tissue Biology Vol. 23 (2014) No. 1 p. 83-92 |
関連サイト |
|
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.jstage.jst.go.jp/article/jhtb/23/1/23_83/_article/-char/ja/ |
|
|
関連名称 |
J-STAGE |
著者版フラグ |
|
|
出版タイプ |
VoR |
|
出版タイプResource |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |